Get the test CWBSP certification is not achieved overnight, we need to invest a lot of time and energy to review, and the review process is less a week or two, more than a month or two, or even half a year, so CWBSP exam questions are one of the biggest advantage is that it is the most effective tools for saving time for users. Users do not need to spend too much time on CWBSP Questions torrent, only need to use their time pieces for efficient learning, the cost is about 20 to 30 hours, users can easily master the test key and difficulties of questions and answers of CWBSP prep guide.
Topic | Details |
---|---|
Topic 1 |
|
Topic 2 |
|
Topic 3 |
|
Topic 4 |
|
>> CWBSP Test Collection Pdf <<
The TorrentExam is one of the top-rated and renowned platforms that has been offering real and valid Certified Water-Based Systems Professionals (CWBSP) exam practice test questions for many years. During this long time period countless Certified Water-Based Systems Professionals (CWBSP) exam candidates have passed their dream certification and they are now certified NFPA professionals and pursuing a rewarding career in the market.
NEW QUESTION # 51
What is the minimum exposed barrel length for a dry sprinkler barrel exposed to 50°F (10#) when the discharge end is in an environment of -30°F (34#)?
Answer: B
Explanation:
For dry sprinklers, the exposed barrel length must be sufficient to prevent freezing. In extreme temperature differentials, such as from 50°F to -30°F, a longer barrel length, such as 18 inches, may be required to ensure the sprinkler remains functional.
References: NFPA 13 guidelines for the installation of dry sprinklers, considering the insulation and barrel length requirements to prevent freezing in cold environments.
NEW QUESTION # 52
What is the maximum distance an underground main can be installed under the building to the riser location without additional requirements?
Answer: B
Explanation:
NFPA standards allow a certain distance for underground mains to run under a building to the riser without imposing additional requirements. A distance of up to 5 ft is commonly accepted, providing a practical allowance for connecting the underground water supply to the building's sprinkler system while minimizing potential risks.
References: NFPA guidelines for the installation of fire sprinkler systems, including considerations for underground water supply connections.
NEW QUESTION # 53
What is the equivalent length of a 45° elbow of 6 in (150 mm) Schedule 10 pipe?
Answer: A
Explanation:
The equivalent length of a 45° elbow for 6 in Schedule 10 pipe is often considered to be around 11.8 ft, accounting for friction loss and the impact on water flow. This equivalent length helps in hydraulic calculations to ensure the sprinkler system meets the required design criteria for pressure and flow.
References: NFPA 13 and hydraulic calculation principles used in the design and installation of sprinkler systems, including considerations for pipe fittings like elbows.
NEW QUESTION # 54
What is the maximum floor area that can be protected by a single ordinary hazard sprinkler system?
Answer: D
Explanation:
The maximum floor area on any one floor to be protected by sprinklers supplied by any one sprinkler system riser or combined system riser shall be as follows:
1.Light hazard - 52,000 ft2 (4830 m2)
2.Ordinary hazard - 52,000 ft2 (4830 m2)
3.* Extra hazard - Hydraulically calculated - 40,000 ft2 (3720 m2)
4.High-piled Storage - High-piled storage (as defined in 3.3.100) and storage covered by other NFPA standards - 40,000 ft2 (3720 m2)
5.In-rack Storage - 40,000 ft2 (3720 m2)
NEW QUESTION # 55
When using a 1.5 in. (40 mm) outlet on a hose connection, an approved pressure-regulating device shall be installed when the residual pressure exceeds what value?
Answer: D
Explanation:
When the residual pressure at a 1.5 in. hose connection exceeds 100 psi, an approved pressure-regulating device is typically required to ensure user safety and to prevent damage to equipment connected to the hose outlet. This helps maintain manageable hose stream pressures for firefighting operations.
References: NFPA standards for the installation and use of hose connections in sprinkler systems, focusing on safety and operational effectiveness.
NEW QUESTION # 56
......
In the major environment, people are facing more job pressure. So they want to get CWBSP certification rise above the common herd. How to choose valid and efficient CWBSP guide torrent should be the key topic most candidates may concern. So now, it is right, you come to us. Our company is famous for its high-quality in this field especially for CWBSP Certification exams. It has been accepted by thousands of candidates who practice our study materials for their exam.
CWBSP Certification Cost: https://www.torrentexam.com/CWBSP-exam-latest-torrent.html
DOWNLOAD the newest TorrentExam CWBSP PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1Njh-QmIK2uJg_2-DOiniGAZ2Pqr_tT1f